Mostrar el registro sencillo del ítem

dc.contributor.authorOrostegui Melendrez, Nicool Betsabe
dc.contributor.authorGodos Malca, Ingri Tatiana
dc.contributor.authorChahuares Paucar, Leonel
dc.date.accessioned2025-04-23T15:53:08Z
dc.date.available2025-04-23T15:53:08Z
dc.date.issued2024-11-08
dc.identifier.citationOrostegui Melendrez, N. B., Godos Malca, I. T., & Chahuares Paucar, L. (2024). Evaluación de las propiedades físicas y mecánicas de ladrillos elaborados con lodos residuales de plantas de tratamiento de agua potable y aguas residuales. Gaceta Técnica, 26(1), 18-34. https://doi.org/10.51372/gacetatecnica261.2en_US
dc.identifier.govdocpp 1999907LA2
dc.identifier.govdocppi201602LA4730
dc.identifier.issn1856-9560
dc.identifier.issn2477-9539
dc.identifier.urihttp://bdigital2.ula.ve:8080/xmlui/654321/16593
dc.description.abstractEn esta investigación se tuvo como objetivo evaluar las propiedades físicas y mecánicas de ladrillos utilizando lodos residuales provenientes de plantas de tratamiento de agua potable y de tratamiento de aguas residuales. Para tal efecto, se hizo un estudio experimental y comparativo donde se seleccionaron como muestra 20 ladrillos elaborados con 50% de lodos residuales, los mismos fueron confrontados con 20 ladrillos tradicionales (Pirámide 18H). Según los resultados, se ha identificado que la resistencia a la compresión en los ladrillos tradicionales corresponde a 14,73 MPa; estando dentro del tipo IV y tipo V; en tanto, la resistencia en los ladrillos con lodo (Toby) es 7,11 MPa, los mismos que están considerados en los ladrillos tipo I y II.en_US
dc.description.abstractThe objective of this research was to evaluate the physical and mechanical properties of bricks using waste sludge from drinking water treatment plants and wastewater treatment plants. For this purpose, an experimental and comparative study was carried out where 20 bricks made with 50% waste sludge were selected as a sample, they were compared with 20 traditional bricks (Pyramid 18H). According to the results, it has been identified that the compressive strength in traditional bricks corresponds to 14,73 MPa; being within type IV and type V; meanwhile, the resistance in bricks with mud (Toby) is 7,11 MPa, the same as those considered in type I and II bricks.en_US
dc.language.isoesen_US
dc.publisherUniversidad Centroccidental Lisandro Alvaradoen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/3.0/ve/en_US
dc.subjectMateriales estructuralesen_US
dc.subjectResistencia de materialesen_US
dc.subjectLodos de aguas residualesen_US
dc.subjectEnsayos de materialesen_US
dc.subjectStructural materialsen_US
dc.subjectStrength of materialsen_US
dc.subjectWastewater sludgeen_US
dc.subjectMaterials testingen_US
dc.titleEvaluación de las propiedades físicas y mecánicas de ladrillos elaborados con lodos residuales de plantas de tratamiento de agua potable y aguas residualesen_US
dc.title.alternativeEvaluation of the physical and mechanical properties of bricks made with waste sludge from drinking water and wastewater treatment plantsen_US